Contact the distributor of the file. Right-click the Static VI Reference function on the block diagram and select Browse for Path. Numeric return types are passed by value. As a result, when you try to access that VISA session using a global variable, you can get an invalid VISA session error if the option is enabled.In LabVIEW 6 and weblink

To disable automatic error handling for any new, blank VIs you create, select Tools»Options and select Block Diagram from the Category list. Verify the ability name does not contain spaces. 1469 Specified ability already exists. If you wire the error cluster to the conditional terminal, only the TRUE or FALSE value of the status parameter of the error cluster passes to the terminal. In this case, disabling theAutomatically Close VISA Sessionsoptioncan prevent the error. http://digital.ni.com/public.nsf/allkb/F3E0621CB71AA16786256F970000FC57

Labview Visa Error -1073807339

Check printer configuration. 1016 Cannot load History. 1017 VI has been modified on disk since it was last loaded or saved. 1018 Unspecified error occurred. 1019 One or more untitled subVIs Please tell us why. The palette view format must be Icons, Icons and Text, or Text.

Almost all I/O functions return error information. General Error Handler Simple Error Handler You also can select Help»Explain Error to display an error code description in the Explain Error dialog box. After using a serial VI the default behavior of LabVIEW is to not release the serial port. Labview Visa Error Codes Poor|Excellent Yes No Document Quality?

Check to make sure your cables are securely plugged in. 4. Daqmx Error Codes Your cabling may be loose. NoteYou must manually create an errors folder in the labview\user.lib directory to organize your error code files. Read More Here Primary Software: Driver Software>>NI-DAQmx Primary Software Version: 8.6.1 Primary Software Fixed Version: N/A Secondary Software: LabWindows/CVI Run-Time Engine Problem: I need to do error checking in a programming environment other than

User-Defined Error Codes National Instruments recommends that you use the General Error Handler VI to define custom error codes. Labview Error 200279 o In LabVIEW 6.x and 7.x, selectTools»Optionsto display the Options dialog box. Verify the values you wired to the Open VI Reference function. 1097 An exception occurred within the external code called by a Call Library Function Node. Stopping a While Loop Learn LabVIEW Basics in a New Way Learn these LabVIEW concepts though our new, interactive experience.

Daqmx Error Codes

To correct this error, save to a folder instead of an LLB. 1497 Cannot unlock a library for edit when instances in running VIs exist. 1498 Library has errors. https://zone.ni.com/reference/en-XX/help/371361H-01/lvhowto/find_error_descriptions/ Due to race conditions that can occur when you have a Boolean value with latching mechanical action, you cannot programmatically read Boolean values that are set with a latching mechanical action. Labview Visa Error -1073807339 Note: If you disable this option, then make sure you are callingVISA Closewhen you are finished communicating with the device. Labview Error Daqmx Change the display mode to 0 (normal) and/or disable word wrapping to use this property. 1363 The specified name or GUID is invalid. 1364 The provider plug-in is not installed or

You do not have the correct permissions for the file. have a peek at these guys This can result in a temporary phase shift, which would alter the update period for NI Scan Engine variables for one iteration. Related Links: KnowledgeBase 21O7DELI: Error -37 When Using the Serial Compatibility VIs Attachments: VISA Close.vi Report Date: 01/14/2002 Last Updated: 05/10/2016 Document ID: 2HDGKBOH Your Feedback! Undefined errors might occur if a description does not exist for the error code. Labview Error 1073807339

Right-click the graph or chart and deselect Autosize Plot Legend in the shortcut menu to disable automatic resizing and make sure you arrange the plot legend vertically. 1484 LabVIEW cannot inline To disable automatic error handling for a subVI or function within a VI, wire its error out parameter to the error in parameter of another subVI or function or to an You often can solve the problem by taking the following actions. http://edsdefence.com/labview-error/labview-error-10.php Your cache administrator is webmaster.

Most likely the VI is broken or one of its subVIs cannot be located. Error Labview Fpga or @. 2 Memory is full. 4 End of file encountered. 5 File already open. 6 Generic file I/O error. Many error code text files are found in [National Instruments]\Shared\Errors as shown below.The error codes for the Modular Instrument drivers, which include drivers such as NI-SCOPE and NI-DMM amongst others, can

This error occurs when you try to use the Active Frame property with a Conditional Disable structure.

To correct this error, wire the required input. 1398 The subVI cannot be inlined because there is a local variable in the block diagram. 1399 The subVI cannot be inlined because The specified file is not a valid palette file (.mnu). This option helps you avoid potential problems the next time you run the VI. Labview Fpga Error Code For example, if LabVIEW encounters an error, you can display the error message in different kinds of dialog boxes.

My Profile | RSS | Privacy | Legal | Contact NI © 2014 National Instruments Corporation. This description is the same description that appears in this help file. The text files relating to particular drivers contain error codes go in order, and thus you can get the ranges for each driver.Additional information about LabVIEW error codes can be found this content Refer to the LabVIEW Help for a list of valid versions. 1526 This property does not apply when the plot legend of a graph or chart is in tree view. 1529

Automatic Error Handling Back to top Each error has a numeric code and a corresponding error message. To resolve this error, give the file a unique name that does not already exist in the application instance. 1052 The LabVIEW filename is invalid. 1054 The specified object was not You cannot get a new reference to the application instance or load a VI in the application instance. 1533 A shared variable node cannot be created from the specified terminal. 1534 This file cannot be saved until all dependent files have been named. 1022 Wizard Template not found. 1023 Wizard template does not have a diagram. 1024 Call Instrument aborted. 1025 Application

If this error occurs, you must enable buffering and reopen the file. 1546 The VI must be in a project to use this property. 1548 Queue refnum cannot be obtained with You cannot add an ability multiple times. 1470 Specified folder is outside the library. The device will continuously output the data whether the program is on or off. The following are some suggestions and ideas for ways to identify and handle undefined errors.

The sound format of this file is not recognizable. A possible cause for this error is the disk or hard drive to which you are trying to save might be full.