Home > Labview Error > Labview Error Code

Labview Error Code

Contents

To correct this error, ensure the target VI is idle or reentrant. For example, enter Ignore this message. The requested entry could not be found. −120000 LabVIEW SignalExpress is required to open this ExpressVI. Press the key or click anywhere in the dialog box to display a description of the error code in the Explanation field. weblink

You cannot use queues for communication between LabVIEW application instances. 1492 If you obtain a notifier reference in one application instance, you cannot use that notifier reference in another application instance. Use the VISA Close VI in the VISA Advanced palette. Just wanted to mention this, because it does not seem that your tip to use "C" instead of "Win API" in clf nodes works for me on LabVIEW 2010 (which is All rights reserved.| Cart|Help KnowledgeBase Request Supportfrom an engineer NIHome > Support > KnowledgeBase English 83 ratings: 3.02 out of 5   Why Do I http://zone.ni.com/reference/en-XX/help/371361J-01/lverror/misc_lv_error_codes/

Labview Visa Error -1073807339

Another possible cause for this error is there might be a bad network connection. Unnamed mechanisms do not have this restriction, because each request to obtain an unnamed mechanism creates a new mechanism. One of the specified arguments is invalid. −1967345147 Entry not found. To correct this error, verify that the file is not in use by another application and that file permissions are set correctly.

Now when I call the clf node, LabVIEW (I'm on 2010 now) crashes. The specified access type is not valid. −1967345148 Invalid argument. Feel free to reply to my posts even if they are not directed to you, but please be respectful and professional. Labview Error 1073807339 For example, hexadecimal notation is not a valid format for floating point numbers. 1434 The precision is greater than the maximum allowed value for this format. 1436 Numeric precision cannot be

You must use an absolute path. 1432 The specified format cannot be used with floating point data. Daqmx Error Codes You cannot use notifiers for communication between LabVIEW application instances. 1493 The save operation failed because multiple files of the same name cannot be saved into a single LLB. Each element of the cluster must have either a unique name or no name, such as an empty string. −375001 The JSON root container must be an array or cluster. −375000 The specified sound file could not be found. 4806 DirectX 8.0 or higher is required to run.

This error also can occur if you attempt to obtain a VI's image while the VI is being modified programmatically. Labview Error 200279 The exception might have corrupted the LabVIEW memory. What I wanted to mention though is that I tried changing the clf node from Win API to C. Recompiling the VI may fix this issue. 1616 The path to save the report is not valid.

Daqmx Error Codes

Refer to the Connection Responsiveness: Check Method topic in the LabVIEW Help for more information about connection polling. 1131 You cannot use this property with this system control. 1135 The tree Double-click the numeric constant and enter a number within the range of -8999 to -8000, 5000 to 9999, or 500,000 to 599,999 in the array. Labview Visa Error -1073807339 An input task might stop running if the input buffer overflows. Labview Error Daqmx Refer to the KnowledgeBase for more information about correcting errors in LabVIEW.

Make sure you installed Microsoft Word correctly. 1620 LabVIEW is unable to create the Microsoft Word report. have a peek at these guys The input string does not contain data in the expected format. To correct this error, set the minimum size of the pane to a smaller value, or wire a value to the Splitter Position property that does not shrink the pane beyond However, you also can define custom error codes by creating an XML-based text file and adding the error codes and messages to the text file. Labview Visa Error Codes

Make sure you have LabVIEW, NI Serial, and NI VISA on your computer. You also cannot assign the same string value to two or more strings in a combo box control. This error occurs when you use an index value that is out of range to access a frame in a Case, Stacked Sequence, or Event structure. 1313 You cannot use this check over here Right-click the container border and select Replace or drag new subtype. 1096 The Open VI Reference function cannot prepare a non-reentrant VI for reentrant run.

Then choose the correct function name. 1579 Specified paths do not share a common directory. Labview Fpga Error Code A buffer underflow has occurred because the application is not writing data quickly enough. −4803 The sound driver or card does not support the specified operation. Select Customize┬╗View This Palette As from the Controls or Functions palette to change the palette view format. −4401 The specified file is not a valid palette file (.mnu).

The 0x08 flag is useful when running VIs with the Run VI method.

The sound driver or card cannot accommodate the specified configuration. There are duplicated items in the array. 1304 The array index is outside of the array bounds. 1305 The required page cannot be found. 1306 Unable to load new code resource A format specifier does not match the data type of its corresponding argument in a Format Into String or Scan From String function. 82 Unknown format specifier. Error Labview Fpga To resolve this error, give the file a path that does not already contain a LabVIEW file in any open application instance. 1358 The splitter bar cannot be moved to this

The exception might have corrupted the LabVIEW memory. Open the Execution page of the VI Properties dialog box to change the settings for the VI execution. 1006 FPDCO on connector pane thinks it is constant. 1007 No IP record TipActiveX error codes are documented by Microsoft in winerror.h. this content Ensure that the parameters values are within the supported range for the hardware and drivers. −4406 A VI item in the palette data array is not supported in this version of

This problem might occur due to a type cast error. 1564 Project file cannot be saved at this time. If the VI or function does not have error out, you can edit the error handling within the VI or function to avoid this error. One of the specified arguments is invalid. −1967345147 Entry not found. The distributor must include compiled code in the file for it to run in the LabVIEW Run-Time Engine. 1575 The function name for the %s node cannot be found in the

The values were clipped to fit within this range. −4820 A buffer underflow has occurred. The return type must be Void, Numeric, or String.