Home > Labview Error > Labview Error Code -52005

Labview Error Code -52005

Contents

The lock prevents giving the untitled item a name so it cannot be saved. 1571 You cannot open a packed library saved in a version earlier than the current version of To set the state of the open front panel, use the Front Panel Window:State property. 1151 Invalid input for front panel state. 1156 Memory full error, possibly due to a data Answered Your Question? 1 2 3 4 5 Document needs work? If you receive this error while trying to build an executable in LabVIEW 8.5 or later with the Report Generation toolkit 1.1.2 or later , refer to the KnowledgeBase at ni.com weblink

This mismatch implies that the dependency report is unreliable, so the ReadLinkInfo operation was aborted. 1595 The RT target does not have enough memory to load the startup application. 1596 Cannot An input task might stop running if the input buffer overflows. Make sure you installed Microsoft Word correctly. 1624 You can only generate web page or plain text reports on OS X and Linux. 1627 The control index at position %d is If you receive this error while using a File I/O function or VI, you may be attempting to overwrite a file or folder that already exists. http://zone.ni.com/reference/en-XX/help/371361J-01/lverror/misc_lv_error_codes/

Daqmx Error Codes

Legacy or Third-Party Drivers If you are using a driver that was released before LabVIEW 6.1, the driver installed a version of error.llb that contains all the driver error codes. Save any work to a new location and restart LabVIEW. 1144 Cannot insert VI in a subpanel control because VI is already open. 1145 Cannot open VI because it is already Another application is currently using the device.

This is due to lack of sufficient privileges for the current user or machine. 0 Operation completed successfully. 1073676290 Specified event is already enabled for at least one of the specified The input for class name is not correct or is in the wrong format. The disk or hard drive does not have enough free space to complete the operation. Labview Error 200279 There are duplicated items in the array. 1304 The array index is outside of the array bounds. 1305 The required page cannot be found. 1306 Unable to load new code resource

LabVIEW cannot return a reference to the semaphore. Labview Visa Error -1073807339 This error occurs in stand-alone applications when the VI is polymorphic. Without a mechanism to check for errors, you know only that the VI does not work properly. http://digital.ni.com/public.nsf/allkb/FD9FEFCDD2F95C29862572AA006AC909 If the VIs do not return a description, the error code text files might have been moved, deleted, or corrupted.

If you receive this error while trying to run File I/O VIs, refer to the KnowledgeBase at ni.com for more information. 2 Memory is full. Labview Visa Error Codes or (OS X/Linux) < > \ | : " * ?. 1617 LabVIEW is unable to generate a VI comparison report. When strict validation is enabled, the number of elements in the JSON string must match the number of elements in the input cluster. −375005 Type mismatch between JSON and LabVIEW. −375004 When a Boolean control is configured with a latching mechanical action, the Value property always returns an error.

Labview Visa Error -1073807339

If create if not found? http://zone.ni.com/reference/en-XX/help/371361M-01/lverror/misc_lv_error_codes/ To correct this error, set the minimum size of the pane to a smaller value, or wire a value to the Splitter Position property that does not shrink the pane beyond Daqmx Error Codes To correct this error, install the latest version of DirectX from http://www.microsoft.com/downloads. 4810 Cannot recognize sound format. Labview Error Daqmx This file cannot be saved until all dependent files have been named. 1451 One or more untitled dependencies exist.

Void can be used only as return type of function. 1186 Cannot show or hide the label on its own. have a peek at these guys The driver did not install error code text files to describe the driver error codes. User-Defined Error Codes National Instruments recommends that you use the General Error Handler VI to define custom error codes. Applications or Shared Libraries If you are developing an application or shared library, you must distribute any relevant error code text files with the application or shared library. Labview Custom Error Codes

Double-click the string constant and enter a description in the user-defined description array. This file cannot be saved until all dependent files have been named. 1451 One or more untitled dependencies exist. Verify the ability name does not contain spaces. 1469 Specified ability already exists. check over here This calculation leads to erroneous results if data is appended to the waveform.

You can define custom error codes in the range of -8999 through -8000, 5000 through 9999, or 500,000 through 599,999. Labview Error 50103 All rights reserved. | Cart|Help You are here:NI Home > Support > Manuals > LabVIEW 2012 Help VISA Error Codes »Table of Contents LabVIEW 2012 Help Edition Date: June code is a 32-bit signed integer that identifies the error numerically.

Frequency domain waveforms are constructed with a base frequency f0 and a delta frequency df.

To correct this error, ensure that the names you use for drag data are unique in each element of the data array for the method or event. 1385 Cannot start a You often can solve the problem by taking the following actions. You can use the Strip Path function to wire the filename as a string, but this will not work for VIs in libraries. 1447 There was a name conflict while saving Labview Error 1073807339 The specified privilege ID is out of range. −1967345149 Invalid access type.

Check printer configuration. 1016 Cannot load History. 1017 VI has been modified on disk since it was last loaded or saved. 1018 Unspecified error occurred. 1019 One or more untitled subVIs Add the General Error Handler VI to the block diagram. A VI can open VI Server references only to other VIs that it could call as subVIs. this content Supported data types include arrays and clusters of booleans, numerics, strings, and other arrays and clusters. −120000 SignalExpress is required to open this Express VI.

This normally is a user data file. 99 Incorrect file version. A VI is reserved for running when you open a reference to the VI by wiring a type specifier VI Refnum to the Open VI Reference function, or when you have You cannot use queues for communication between LabVIEW application instances. 1492 If you obtain a notifier reference in one application instance, you cannot use that notifier reference in another application instance. This error can occur if you use a VI that is not supported in the LabVIEW Run-Time Engine. −4404 The value for palette width is invalid.

When you perform any kind of input and output (I/O), consider the possibility that errors might occur. Ensure that a task is active and try again. Another possible cause for this error is there might be a bad network connection. The lock prevents giving the untitled item a name so it cannot be saved. 1571 You cannot open a packed library saved in a version earlier than the current version of

Change the execution mode of the referenced VI to reentrant for this operation. 1301 The dimension of the array passed in does not match the expected dimension for the operation. 1303 Answered Your Question? Stopping a While Loop Learn LabVIEW Basics in a New Way Learn these LabVIEW concepts though our new, interactive experience. Use error handling with the debugging tools to find and manage errors.

Error message from server: %s. 1090 Specified object cannot be moved. 1091 The VI Server or client received an unrecognized message. 1094 Queue and notifier references of the same name must Double-click the VI or function and replace the general error handling with an error out indicator or some other form of error handling. The requested entry could not be found. −375012 A JSON numeric value is out of the range of a LabVIEW numeric type. −375011 LabVIEW failed to read or write a -Infinity You also can receive this error if the Scan From File or Scan From String functions reach the end of the file.

Attempted to read from or write to a file of a version incompatible with the write/read function version. You can use this property only with the Conditional Disable structure. 1377 A Diagram Disable Structure cannot have conditions. To set the state of the open front panel, use the Front Panel Window:State property. 1151 Invalid input for front panel state. 1156 Memory full error, possibly due to a data If the VI or function does not have error out, you can edit the error handling within the VI or function to avoid this error.

Enter a path to an existing palette file to read data from the palette file. A timeout error occurred because the application was unable to successfully acquire a mutex. 4823 You cannot perform this operation without an active task.