Home > Labview Error > Labview Error Code 1026

Labview Error Code 1026

I haven't been able to find documentation on this feature. This item has been edited in another context on this machine. You can use this property only with a Diagram Disable structure. 1380 License checkout failure. What does the above error mean, in English? http://edsdefence.com/labview-error/labview-error-1026.php

You cannot use queues for communication between LabVIEW application instances. Is there a link to a "known bugs" list for the framework that FRC teams can view? ~ Ether View Public Profile Find all posts by Ether Find CD-Media Photos by I’ve also attached an example VI that uses multiple subVIs and a subpanel for reference. Code Description −2147467259 Unspecified error. −1967345152 Invalid refnum. More hints

Code resource already loaded. 1307 Subpanel control could not open the VI window. This is caused by trying to allocate a buffer that is too large for memory. Back to Forum Index : Back to Driver Questions You must be logged in to post a reply You need to Register or Log In before posting on these forums. The specified wave format is not supported.

This error occurs when you try to use the Active Frame property with a Conditional Disable structure. I've never noticed other 1026 errors, whereas there should have been some coincidental calls by now in al the times that the program has been running. OCCRA When motors stall, bad things happen. - Rob Stehlik [more] Chief Delphi > Technical > Programming > NI LabVIEW ERROR 1026 User Name Remember Me? Only one VI can call any given subVI at a time -- if you want more than one to be able to call simultaneously, make the VI reentrant, which is, in

Most of these calls are brief, but one (load a file) can take several seconds, depending on the file size. is FALSE and a queue or notifier with that name was not found, LabVIEW returns this error. 1102 The string wired to the xml string input is empty. 1103 The XML But, if I ask the functional global to read a really large file, which takes seconds, then a simultaneous call from another VI gives 1026. http://digital.ni.com/public.nsf/allkb/23A998FB0A7E2CA48625796C0044D815 If you’re still having issues, could you post some screenshots or your actual VI?

A VI can open VI Server references only to other VIs that it could call as subVIs. A specified refnum was not valid. −1967345151 Invalid property code. The NI application engineers there will be able to dig deeper into it and figure out if you've got a bug or not. If necessary copy in the error info, such as entering in 1026 in the decimal error, and it tells you that this indicates a bad VI refnum was wired in as

Is it a shared machine, and is the current user an administrator on the machine?I am not able to attach files here, so I created a forum post to attach an https://forums.ni.com/t5/LabVIEW/error-1026/td-p/893645 Sign In Sign In Remember me Not recommended on shared computers Sign in anonymously Sign In Forgot your password? To resolve this error, give the file a unique name that does not already exist in the application instance. 1052 The LabVIEW filename is invalid. 1054 The specified object was not Try freeing up disk space or saving to a different disk or drive. 10 Duplicate path. 11 Too many files open. 12 Some system capacity necessary for operation is not enabled.

Aristos, Didn't see your post until just after I replied. have a peek at these guys It makes a certain amount of sense, but surprises me since it apparently isn't documented. You cannot use this property with a Conditional Disable structure because conditions determine the active frame. Guru, Interesting idea.

For example, the network connection is down or a network cable is unplugged. 8 File permission error. An array must have 1 or more dimensions. 1176 Invalid waveform dimension in Call Library Function Node configuration. For example, use \ as path separators on Windows, : on Mac OS X, and / on Linux. check over here Frequency domain waveforms are constructed with a base frequency f0 and a delta frequency df.

Double-click the VI or function and replace the general error handling with an error out indicator or some other form of error handling. You must create these objects in the LabVIEW development system. 1124 VI is not loadable. All rights reserved.| United States MY ACCOUNT   INNOVATIONS SHOP SUPPORT COMMUNITY Home Community Home : Discussion Forums : Most Active Software Boards : LabVIEW : error 1026 invalid reference at

Just select it and on the menu to the right select uninstall.

Refer to the National Instruments Web site to download the VIs. 1196 Cannot list the same terminal more than once in the grown region of the expandable subVI. 1197 This operation There are more format specifiers than the number of arguments of a Format Into String or Scan From String function. 85 Scan failed. I've never seen a problem with this and I'd have to see some code to make any guesses about what is wrong. Refer to the KnowledgeBase for more information about this error. 1074 Cannot create a control/indicator for the specified terminal. 1075 Cannot create a constant for the specified terminal. 1076 VI is

To do this open the vi 'Cscope vi container.vi' from the Cscope Control Driver.llb, and then do a 'Save All'. The frequency for a data point is then calculated as f0+N*df. The Connectivity VIs are available for free download from ni.com. http://edsdefence.com/labview-error/labview-error-1026-invoke-node.php Thanks, DaveT Share this post Link to post Share on other sites Yair 218 Extwemely Active Members 218 2,829 posts Version:LabVIEW 2009 Since:2003 Posted February 17, 2008 I think the

I would expect that the LV scheduling system would queue up requests to the functional global like it would for any other sub-vi call. Fix the errors before attempting this operation. 1499 Library has edits in another context. Or sign in with one of these services Sign in with Facebook Sign in with Twitter Sign in with LinkedIn Sign Up All Content All Content This Topic This Forum Advanced