It is not because of any instrument or GPIB device malfunction. Select the option that matches the hardware you're using as a CAN gateway, and Apply the changes. We know it isnt an update since it worked for a week after them. It may be that when building the executable, it may not be building it to include all your files in a single target file. weblink

Make sure the checkbox next to NiVisaTulip.dll is checked. Thanks, Brad If you would like to refer to this comment somewhere else in this project, copy and paste the following link: cpol2014 - 2014-07-17 Hi, I'm having your same problem. Labview was giving the error, “Error 7” with something about “Board Missing”.This error means that LabView cannot locate the GPIB interface “board”. While if I run the "test_all.vi" I get the message "91 occurred at Variant To Data in test_variant.vi->test_all.vi". Bonuses

Labview Error 7 Open File Vi

All rights reserved. | Cart|Help KnowledgeBase Request Supportfrom an engineer NIHome > Support > KnowledgeBase English 59 ratings: 4.20 out of 5   Error 7 Explicitly specify a path in that string to the location of the VI. Poor|Excellent Yes No Document Quality? If the default file name is blank, Open File.vi *may* prompt for a file name (I can't remember).

Please tell us why. Select _Excel Dynamic VIs.VI then click OK.If using Microsoft Word, please include the pathLabVIEW 7.x\vi.lib\addons\_office\_wordsub.llb. The two solutions to this problem are described below. The cause of this error is when a VI or subVI includes a dynamic VI reference without an explicit path.

Is there an error code reference somewhere? Please don't fill out this field. Can you create a Call Library Node to that DLL on a blank VI and check that it can access it? https://forums.ni.com/t5/LabVIEW/Error-7-File-not-found-for-executable/m-p/1922139 You select the plugin from the available options in the FRC 2012 cRIO Imaging Tool.

Poor|Excellent Yes No Document Quality? My tests indicate error 7 means it couldn't find h5labview32.dll, whereas error 13 means it can't find hdf5.dll or dependencies. Solution: This happens when the Report Generation Toolkit's dynamic VIs are not included during the build process. If using Microsoft Excel, please include the pathLabVIEW 7.x\vi.lib\addons\_office\_exclsub.llb.

Labview Error 7 Occurred At Open File

On the development machine the file paths of these VIs would look like the following: C:\AAA\Main.vi
C:\BBB\Second.vi Previously, if you build an executable in LabVIEW 8.x called Application.exe, the relative Thanks. Labview Error 7 Open File Vi I try to create the same executable in a later version of LabVIEW, but when I run the executable I receive the following error: Error 7: Possible Reason(s): File not found Labview Error 7 File Not Found In the Source File Settings(LabVIEW 8.0 - 8.2) / Source Files(LabVIEW 8.5 - 8.6) category, ensure the dynamically referenced VI is Always Included.

All of the code seems to be in the proper directories. have a peek at these guys The absolute path (although this is not an issue - see previous comment) is not possible given that this is built into an installer and deployed on other platforms (on which Please Contact NI for all product and support inquiries. Also, the config VIs are called in the main application with no problem. Labview Error Codes

If that still looks good, I'd be glad to look at your code... The VI successfully runs in LabVIEW and there were no errors during the build process. sort of VIs) is very touchy. http://edsdefence.com/labview-error/labview-error-10.php Very frustrating.

All Rights Reserved. In LabVIEW, go to Tools » Build Applications or Shared Library (dll) and ensure that the Single target file with external file for subVIs option is selected. Ask the person who imaged your cRIO what they chose.

Nevertheless, it seems to me that there is no issue of the exe finding a vi, but finding a *.cfg file.

In this case, it loads and is running (can check this through debugging). This hierarchy can be seen in LabVIEW by going to the View menu and clicking VI Hierarchy. That would explain why this is happening in both the development environment and executable. Good Luck!

Thanks for all of your responses. Is Labview RT Supports HDF5 file format? One thing that may help that I neglected to mention is that, in the development environment, I can run the calling VI one time and I get the error. this content If a path is not specified when creating a dynamic reference, LabVIEW expects the VI to be within the library.

Why is this and how can I fix it? The instructions on the FAQ are likely out of date, as I am in the process of changing the DLL resolution to fix behaviour on compiled targets. Matt 0 Kudos Message 7 of 20 (5,460 Views) Reply 0 Kudos Re: Error 7: File not found for executable Norbert_B Proven Zealot ‎03-21-2012 09:55 I have had the code working no problem before so this problem has just arose over the past week.

have a great day.