Home > Labview Error > Labview Error 1

Labview Error 1

Contents

My recommendated changes to EndUpdateResource.vi: Swap the error inputs of merge error. On Windows, navigate to the file, right-click the file, select Properties, and set the Read-only option in the dialog box. If the file name you specified contains one of these characters, remove it and you should be able to build your executable without a problem.This error can also be caused by It is probably also bad. http://edsdefence.com/labview-error/labview-error-10.php

You must pass either 1 string or 6 strings. 1524 The target version for save is not formatted correctly. Use the following information as a reference: Error 1 occurred at EndUpdateResourceA.vi Possible reason(s): LabVIEW: An input parameter is invalid. The floating point data was outside of the range [-1.0, 1.0]. Verify the ability name does not contain spaces. 1469 Specified ability already exists. https://forums.ni.com/t5/LabVIEW/Error-1-Message-Input-Parameter-is-Invalid/td-p/223830

Labview An Input Parameter Is Invalid

In this case, the refnum pertaining to the configuration file is not successfully passed through the loop. A file path with the filename is required, but the supplied path is a path to a directory. 118 The supplied folder path does not exist. 122 The resource you are A timing source such as IEEE-1588 or GPS modified the global time value on the controller. Solved!

Poor|Excellent Yes No Document Quality? Incyl program .vi ‏816 KB 0 Kudos Message 3 of 6 (1,010 Views) Reply 0 Kudos Re: Error 1 occured at get queue status dkfire Active Participant ‎06-06-2013 09:01 AM Options United States MY ACCOUNT   INNOVATIONS SHOP SUPPORT COMMUNITY Home Community Home : Discussion Forums : Most Active Software Boards : LabVIEW : Build application still fails with error 1 in All rights reserved.

function rather than checking if the string length is zero. 2 Kudos Message 3 of 6 (1,467 Views) Reply 2 Kudos Re: Error 1 at TCP close muks Proven Zealot ‎12-23-2009 Labview Error 6 YourFeedback! There are only two ways to tell somebody thanks: Kudos and Marked Solutions Unofficial Forum Rules and GuidelinesThe discussions from the Advanced User Track is not over. http://digital.ni.com/public.nsf/allkb/DF54DD9E94D46D2886257C4D006A419E Please Contact NI for all product and support inquiries.

This file cannot be saved until all dependent files have been named. 1451 One or more untitled dependencies exist. Refer to the Converting VIs topic in the LabVIEW Help for more information about converting VIs to the current LabVIEW version. 1127 Cannot instantiate template VI because it is already in The front panel must already be open before you close it or set its state. 1150 Cannot open a front panel that is already open. To correct this error, make sure the reference to the semaphore is valid. 1544 LabVIEW attempted a read, write, or seek on a file opened in unbuffered mode, and the data

Labview Error 6

The input for class name is not correct or is in the wrong format. http://forums.ni.com/t5/LabVIEW/Error-1-at-TCP-close/td-p/1044680 Paths to VIs and palette files (.mnu) must be valid. −4402 The palette view format is invalid. Labview An Input Parameter Is Invalid I posted the .vi Thanks EMG_main_v8_post.vi ‏216 KB 0 Kudos Message 7 of 9 (1,012 Views) Reply 0 Kudos Solution Accepted by topic author lav21 ‎08-27-2015 06:09 PM Re: Error Labview Error Codes Note, you can check whether a queue reference is good by creating a custom probe and checking the queue status in it.

Both the 0x80 and 0x100 option flags conflict with the 0x08 option flag. have a peek at these guys Ultimately found to be trying to close the file a second time after already closing it once. You do not have the correct permissions for the file. Check that the parameters entered are within the supported range for the hardware and drivers. 4804 Cannot write in file playback.

To run a VI using a static VI reference, use an Invoke Node to call the Run VI method. You can use the Strip Path function to wire the filename as a string, but this will not work for VIs in libraries. 1447 There was a name conflict while saving Everyone's Tags: bug_fix View All (1) 0 Kudos Message 10 of 14 (2,839 Views) Reply 0 Kudos « Previous 1 2 Next » All Forum Topics Previous Topic Next Topic Privacy check over here Please tell us why.

So please still vote forBetter error descriptions for Application Builder (At the 2nd try the build has worked at least. The timestamp (Time stamp 5) is going out of the producer and into the consumer. So what you really want to do here is have the queue accept a cluster.

Do not dequeue anything in the problem.

This account is no longer active. For getting the windows error call getLastError when the dll call returns 0. (In case windows error is 0 raise an error as fallback.) When the windows error number is unknown, To ensure correct operation, be sure that the For Loop is executed at least one time. You cannot get a new reference to the application instance or load a VI in the application instance. 1533 A shared variable node cannot be created from the specified terminal. 1534

This just happened to me again with the exact same message shb posted. Showing results for  Search instead for  Did you mean:  Reply Topic Options Start Document Subscribe to RSS Feed Mark Topic as New Mark Topic as Read Float this Topic to the I stopped calling them that when I became one." 0 Kudos Message 9 of 14 (2,876 Views) Reply 0 Kudos Re: Build application still fails with error 1 in LV12 shb this content Verify that the path is correct using the command prompt or file explorer.

How do I go about solving it? Move the loop and you will see it. The timestamp (Time stamp 5) is going out of the producer and into the consumer. I put a probe on the name-ref where the error occurs and when there is an error the value is default 0.

If you have re-connected a removable device, you may need to restart LabVIEW to use the device again. 29 Print aborted. 30 Bad print record. 31 Print driver error. 32 Operating Anybody who meet this problem again please try,no matter it works or not, please write it out. 0 Kudos Message 4 of 12 (9,122 Views) Reply 0 Kudos Re: Error 1 You can use this property only with the Conditional Disable structure. 1377 A Diagram Disable Structure cannot have conditions. This mismatch implies that the dependency report is unreliable, so the ReadLinkInfo operation was aborted. 1595 The RT target does not have enough memory to load the startup application. 1596 Cannot

Right-click the Scan From String function and select Edit Format String to configure the format string to match the input data. 87 Error converting to variant. Change the display mode to 0 (normal) and/or disable word wrapping to use this property. 1363 The specified name or GUID is invalid. 1364 The provider plug-in is not installed or There is already a VI in this hierarchy with this name. 1449 Arrays must have at least one dimension and a maximum of 63 dimensions. 1450 One or more untitled library If create if not found?

I hope this helps. 2 Kudos Message 9 of 12 (5,207 Views) Reply 2 Kudos Re: Error 1 Message - Input Parameter is Invalid UNCKai Member ‎06-28-2013 04:58 PM Options Mark